Echelon Institute logo
Echelon Institute
Canadian Water & Wastewater
🏠 Home
📝 OIT Practice
📋 OIT Mock Exam
🎓 Class 1 Exam
📋 Class 1 Mock
💧 C1 Water Practice
📋 C1 Water Mock
📐 C1 Water Formulas
💧 C2 Water Practice
📋 C2 Water Mock
📐 C2 Water Formulas
🦠 C1 WW Practice
📋 C1 WW Mock
📐 C1 WW Formulas
♻️ C2 WW Practice
📋 C2 WW Mock
📐 C2 WW Formulas
💧 C3 Water Practice
📋 C3 Water Mock
📐 C3 Water Formulas
💧 C4 Water Practice
📋 C4 Water Mock
📐 C4 Water Formulas
🏭 C3 WW Practice
📋 C3 WW Mock
📐 C3 WW Formulas
🏭 C4 WW Practice
📋 C4 WW Mock
📐 C4 WW Formulas
🧪 WQA Practice
🔬 WQA Mock Exam
📐 WQA Formulas
🌊 WPI — BC / AB / SK / MB
🌊 WPI C1 Water Practice
📋 WPI C1 Water Mock
📐 WPI C1 Water Formulas
🌊 WPI C2 Water Practice
📋 WPI C2 Water Mock
📐 Formulas
🏭 Process Guide
♻️ Wastewater
⚙️ Pumping
🧪 Chem Calc
🔬 Lab
🗺️ Career Map
📋 Mock Exam
ℹ️ About
🎫 My Passes

🧪 Chemical Feed Calculator

Live dosing calculations for all major water treatment chemicals. Enter your flow rate and target dose — get feed rates instantly.

🟡 Chlorine Calculator

Cl₂ Mass Needed
25 kg/day
25000 g/day
Product Mass
38.46 kg/day
1.603 kg/hr
Feed Rate
17.36 g/min
continuous feed
📐 Formula
Mass (kg/day) = Flow (m³/day) × Dose (mg/L) × 1000 (L/m³) ÷ 1,000,000
Product (kg/day) = Mass (kg/day) ÷ Purity (decimal)
Feed Rate (g/min) = Mass (g/day) ÷ 1440 min/day

📋 Typical Dose Ranges — Quick Reference

ChemicalTypical DosePurposepH RangeKey Note
Chlorine (Cl₂)1–5 mg/LDisinfection6.5–8.5CT value determines effectiveness
Alum Al₂(SO₄)₃10–50 mg/LCoagulation6.5–7.5Consumes alkalinity
Ferric Chloride5–30 mg/LCoagulation5.0–7.0Wider pH range than alum
Lime (CaO)5–50 mg/LpH/Alk adjust8.0–9.5Raises pH and alkalinity
Fluoride (H₂SiF₆)0.3–0.8 mg/LDental healthAnyOntario target: 0.7 mg/L
Polymer (cationic)0.1–2 mg/LCoagulant aidAnyAlways dilute before feeding